Water Softener Sizing Calculator and Analysis. You know, there are various grain capacities water softeners in the market. If you live in an area with iron in the water, you need to adjust your calculation upwards, adding 3 GPG to the hardness total. You should use cylinder calculators or a capacity calculator of water softener to get the capacity. . Step1 :- Get the water analysis. . If Your Daily Grain Requirements Are: You Need a Water Softener With: 0 - 3,500 Grains Per Day. The most common softening capacity for water softeners falls between 24,000 GR and 80,000 GR. 24,000 Grain Capacity. Most often, a five person household will use a 32,000 grain water softener. Resin capacity: 22-28 kilograins/cubic foot of resin (older resin will have the lower capacity) Salt use (NaCl): 6-10 lbs per cubic foot of resin (8-9 lbs. Water Softener Service Water Softener Services 317-537-9707 For a softener with 1.0 cubic feet of resin, set Brine Fill (BF) to 4 minutes. To calculate compensated hardness multiply the ppm (mg/l) of iron (Fe) & manganese alternate between each other and regenerate automatically based on water usage. Convert to horsepower per hour. Fleck 9600 XST. Considering these facts, the 32000 grain softener we are recommending would regenerate about every 8 days. Calculator Assumptions Usable Softener Resin Capacity is 32,000 Grains per ft 3 at 15 lbs per ft 3 salt charge The maximum flow rate for Water Softener Resin Is 7 gallons per minute per ft 3 Softener is 65% full of resin beads If you do not know how hard your water is, you can use this map to get a rough idea. When in doubt, a larger or twin alternating softener . For a softener with 0.75 cubic feet of resin, set Brine Fill (BF) to 3 minutes. Water Softener Capacity: 3,200 x 10 = 32,000 So with this example, you would need a 32,000 grain water softener. Keep in mind, this is an estimated calculation. . Why Program a Water Softener? The softener capacity is calculated in three simple steps: 1. Lenntech Water treatment and Air purification Lenntech, Water treatment and air purification Softeners * Calculation real capacity softener: Divide the mentioned capacity by the hardness reduction, e.g. This type of product is available from all the leading . The longer the time, the more water is added to the brine tank, and the more salt is dissolved. Step 5: Set the Salt Dosage Setting (If Applicable) Step 6: Set the Regeneration Setting. Calculator Assumptions Usable Softener Resin Capacity is 32,000 Grains per ft 3 at 15 lbs per ft 3 salt charge The maximum flow rate for Water Softener Resin Is 7 gallons per minute per ft 3 Softener is 65% full of resin beads If you do not know how hard your water is, you can use this map to get a rough idea. 1) Is the Fleck 5600 a residential water softener? These guides are to be used for quick estimates for both Fleck water softeners . This provides Fill the brine tank with high quality water softener salt. Two cubic feet of salt equates to 40,000 grains. Hi, I'm Heather! not add mg/l as ions and ppm as CaCO3. You also don't have to analyze the products that lack all the critical components. Educating the public on the water in their homes and businesses. A softener is usually sized to regenerate about once per week. Ft3 resin X resin exchange capacity (typically 30,000 grains/ft3) = Grains capacity. One cubic foot of salt equates to 20,000 grains. Softener Operation. Step 3: Set the Clock Settings. Expected % Capacity To minimize hardness leakage and complete resin bed exhaustion, water softeners are usually run up to a certain percentage of theoretical full capacity. Total Hardness (ppm) = Total Hardness (gpg) Example: 118 ppm TH = 6.9 gpg; 17.1 17.1. However, the user needs to understand the formula that manufacturer follow in the production of the water softener for a house. First Name Last Name Email Phone Number Address Where was the system purchased? 4,800 hardness grains per day X 7 days = 33,600 grains per week. If you think your daily water usage is higher, set a higher value. Water Softener Sizing Calculator Use this calculator to size a water softener for your commercial application. By default, the average water usage per person is set at a conservative 50 gallons per day. To convert the measurement, divide the mg/L by 17.1 to get the GPG. I have presented the various entities in the form of an excel sheet, which can be adjusted and understood with ease. You need to apply the exact . If you do not know how hard your water is, you can use this map to get a rough idea. A water softener's capacity is based on the amount of resin inside the unit. Use the online calculator to properly size a softener. The graph at the bottom of the page is a capacity and efficiency vs. salt dosage curve which shows that it is not efficient to program nor use the entire capacity of a water softener. Required water softener capacity = 3000 grains per day x 7 days = 2100 grains per week That means your softener wants 21000 grains of total hardness to regenerate once a week. Flow (LPH) Operating Hours (Hrs) Water Hardness (mg/L) Exchange Capacity (g/L) Typical water softener Note: NaCl required per liter of resin - 150 Grams That's good enough! Determine Maximum Gallons Per Hour Make-up. Then just choose a water softener with the proper grain capacity. AUGUST 6, 2021 Use the calculator below and get a rough idea on the grain capacity required to sufficiently soften your water. The formula of 6 pounds of salt per cubic foot of water softener resin per regeneration to achieve two thirds of the total capacity is what we use in the sizing . Calculate Water Softener Capacity WECO Guide for Proper Water Softener Sizing Step 1 Choose your application MotorHome Residential Commercial WECO Filters aim to provide the most energy and water efficient system that meets the flow rate and available pressure parameters. Water pressure, temperature, flow rate and cubic feet of . But it is also possible to find softeners of up to . Usable Softener Resin Capacity is 32,000 Grains per ft 3 at 15 lbs per ft 3 salt charge. This is due to the way the softening process operates. Step3 :- From the regeneration level select the Exchange capacity from the graph or Table . We use these factors to calculate water softener size with a simple equation: Flow Rate Water Hardness = Total GPD. Step 4: Calculate total grain capacity. It is usually best to get the smallest softener that can meet the flow rate and capacity requirements. Step 4: Set the Hardness Setting. Softener Calculation. This is not a specific ratio but in many calculations in water treatment, it is close enough. Daily Softening Requirement = 10 grains per gallon X 300 gallons per day = 3000 grains per day. Note: Calculations are based upon your softener system regenerating on an average of every 7 days. 2. Use this online softener size calculator to figure out the size you need along with estimated life of media, salt consumption and when the softener will automatically regenerate. Water pressure, temperature, flow rate, and cubic feet of resin per tank are all variables that also have effects on water softener sizing and are not considered. Boiler rating is in pounds per hour of steam. Sheet3 Sheet2 Sheet1 gpp Family Members Gallons per Day Grains per Day Days Between Regeneration (6 is optimal) (To covert hardness in ppm to gpg, divide by 17.1. Convert to grains per gallon (gpg). 6 days between regenerations is probably best - especially . 1 cubic foot of resin can remove 32,310 grains of hard water minerals (calcium, magnesium, iron, and manganese). If the water stops flowing, cover out the water tap & let all air go, then cover up the tap. If the calculation to determine how much hardness passed through the softener over the course of the 1,600-gallon test indicated that it was 650 grains, then the softening capacity of the softener at the tested salt setting would be: 32,000 grains total introduced - 650 grains that passed through (leakage) = 31,350 grains softening capacity Convert water hardness from ppm to grains per US gallon. Assume; there is no iron or manganese in your water. Table of Contents. That's why we at Waternity Lab decided to explain in the most simple terms how to size a water softener. Calculate daily softening. H.P. 3. Hardness: 10 grains per gallon. How much water per day at peak times. Water Softener Capacity Calculation Ideally, a water softener should be sized so that it does not regenerate any more often than every three days (wastes water and salt), nor go longer than 14 days before regenerating (can cause compacting of resin, and fouling with sediment or iron). One GR stands for the1/7000 th of a pound worth of minerals that the softener can remove from your water. Order number Order Date Product Family Model In the example above, the softener will be removing 3000 grains per day. Daily Water Use: 4 People X 75 Gallons per day = 300 gallons per day. View a chart with grain capacities and water softener tank sizes to determine the correct size water softener for you. Service flow: 2-4 gpm/cubic foot of resin; Backwash flow: 6 gpm/square foot of resin (dependent on water temperature) Brine draw flow: 0.5-1.0 gpm/cubic foot of resin Capacity For example . This final number will tell you just how many grains of hard mineral content your ideal water softener can remove. To program a softener, the calculation is each gallon of water entering the brine tank will dissolve 3 lbs salt. 0.75 cubic feet of salt equates to 15,000 grains. Figure out the number of days between regeneration . . Convert H.P. Capacity per Cubic foot of Resin (Grains): Total Gallons of Water Used Between Regenerations: Cubic Feet of Water Softener Resin Needed Per Tank: Inch Valves (estimate): There are many variables in sizing industrial water softeners beyond the scope of the water softener calculator below. Water Softener Capacity: Automatic - Programmable Water Softener/Maintenance Calculation Cartridge Grain Capacity Water Hardness (grains per gallon) = Gallon Capacity of Cartridge Gallons of Water Used per Day = Days Until Cartridge Document Retrieval WATER SOFTENER WITH 12 DAY SERIES TIMER CONTROL INSTALLATION A 1.0 cubic foot quantity of resin can be regenerated with various differing amounts of salt, to achieve different grain capacities: 6 pounds of salt = 20,000 grains 9 pounds of salt = 25,000 grains 15 pounds of salt = 32,000 grains Note: If softener is treating iron Access Document How Do Water Softeners Work - Water Softener Facts approximate demand flow (gallons per minute)with these two components, you can determine approximate daily flow of your softener system and the amount of capacity necessary in a softener tank to last at least 24 hours.below, fill in the approximate hardness value and demand flow for your desired system.with the kilograins of hardness / 24 hrs, Now you know the total consumption in gallons, hardness level, you can use the water softener calculator. This will help you identify the water softener unit with the best salt efficiency. Complete fleck softener working manual: Automatically lead the softener command into the system site to ensure water moves into the resin area. For example . 15 GPG X 320 gallons per day = 4,800 hardness grains per day. How to Program a Softening System . Multiply the answer by your water hardness in grains per gallon (to convert mg/l or ppm to grains, divide by 17.1). This is tutorial video regarding How to calculate softener Capacity ? Slightly hard: 50-100 ppm/3-7 gpg. Multiply the number of people in your family times 70 (gallons of water used per day, national average). You can. The formula is pretty straightforward, multiply the hardness by gallons per day. : The LT-twin-9500-01 by reduction from 8D to 0D has a capacity from 238 / Visit Document The most popular sizes range between 15,000 to 80,000-grain capacity. 342 17.1 = 20 gpg. For the basis of this calculation, with a low organics content I am basing on a gel, polystyrenic, anion resin with a high capacity. Step 5: Consider salt efficiency. Instructions: Enter values in dark yellow fields to see suggested models in table to the right. When it comes to calculating total grain capacity, first of all it is vitall to know that a water softener can only remove a certain number of hardness granules before it has to renew. Factoring in Iron Iron can be exchanged on SAC softener resin too. 24,000-grain capacity 30,000- grain capacity 32,000-grain capacity 48,000-grain capacity 64,000-grain capacity But some go all the way up to 110,000-grain capacity. Note: A single grain is approximately 65 mg - about the weight of a cereal grain like wheat or rye. Water softener size calculators don't really give you the correct grain capacity (instead you get a recommendation of a water softener), and even experts try to get away with 'most households need a 32,000-grain capacity water softener'. Recommendations are designed to regenerate the resin at 80 per cent capacity of the resin, so the number of gallons of water that are available before regeneration is given by (water softener grains capacity x 80%) / adjusted total hardness in grains = (48,000 x 0.8) / 1.93 = 19,896 gallons. Select the number of people that live in your home. All ions should be in the same unit. in Hindi language.In this video explained the procedure of softener capacity calculatio. For Softener Unit Client :- Techpro By Samar Seth. per hour 4.25 = gallons per hour make-up. Most households do not need a softener that size. Dave Consiglio I have one and I know how it works. Locate your serial number Click here to find your serial number Fill in the information below Done! Most homes use a 33,000 grain water softener, but for larger homes with more occupants, more conditioning is required. Use the following formula to calculate the proper size: 1. Softener Operation (Basic Ion Exchange Process) Thumb rules of designing a Softener Step 1 - To Select resin quantity (ltrs) for a particular hardness (ppm) for a particular output (m3) per regeneration per hour based on regeneration level 160 gm/ltr, ion exchange capacity = 55, TDS limit = 1500 ppm refer Table 1 Resin Quanitity = Load (ppm as CaCO3) * Flow * time Ex. Volume. Calculate Water Softener Capacity WECO Guide for Proper Water Softener Sizing. Tip: Common residential sizes include 0.75, 1.0, 1.5, and 2.0 cubic foot systems. per hour to gallons per hour make-up. 1.5 cubic feet of salt equates to 30,000 grains. Step 4 :- Calculate the OBR required . To size water softener for your own household, use the following formula: Average Daily Water Consumption x Water Hardness (grains per gallon) x 7 = Water Softener Capacity Requirement Choosing a Softener to Meet Your Needs Design Calculation. Also. Depending on the water hardness, the 64,000 grain-capacity system can be a good fit for households with up to 6 people. For a 32,000 grain capacity water softener with one (1) cubic foot of resin, regeneration is more efficient after just 20,000 grains of hardness have been removed. What will be the best softener to select? Softener is 65% full of resin beads. Water Softener Sizing Calculator & Water Score Reports. This tool is useful in determining softener resin quantity, OBR (output before regeneration), salt and water requirement during the regeneration process. Water Softener Size Calculator. It is typically assumed that 1 ppm Fe equals 2 ppm Total hardness. Grain capacity ranges from 24,000 to 64,000, and it handles a flow rate of 7 gallons per minute. A typical number used is 90%. Registering your Aquasure Harmony Water Softener system for an additional 4 years is easy. Calculating the Required Grain Capacity Here is a chart which shows resin regeneration capacity at various salt settings. So, water softener capacity determines the capacity of water in one regeneration cycle. 3. A sodium zeolite softener operates through two basic cycles: the service cycle, which produces soft water for use, and the regeneration cycle, which restores resin capacity at exhaustion. Contact Us 818-786-0600 Local/Int. In some water softeners, the regeneration is automatic. 2. 3,501 - 4,500 Grains Per Day. Here are the Brine Fill times to use for the Fleck control valves: For Fleck 5600SXT. Yes, the Fleck 5600 is primarily intended for residential applications. One supplier stated that it takes five to seven pounds of salt . Despite these concerns, a careful analysis of its performance, certifications, and pricing is sufficient to say this product is an excellent choice for any family. Capacity per Cubic foot of Resin (Grains): . Hard: 100-200 ppm/7-11 gpg. Calculator Assumptions. This is tutorial video regarding how to calculate softener capacity in english language In this video explained the procedure of softener capacity calculation in detail step by step. 2. Softener Capacity Calculation Most softeners have these softening capabilities. 32,000 Grain Capacity. The formula to calculate your daily hardness removal requirement is detailed below. The manufacturers engineer the product, keeping in view GR( grains) capacity. There are conditions that would create a need for a larger unit: larger family (6 or more), larger house (4000sq ft+) and/or very hard water (over 15 grains). If one wants a reliable water softener resin replacement, the Aquatrol is an excellent choice. Calculate softener capacity in grains. A commercial water softener sizing calculator is typically easier and accurate than human calculations, so you'll not have to waste your time figuring out which manufacturer is right for you. About the Paper I ,as an intern, calculated the ion exchange softener design for a small sized powerplant of TechPro Inc. in May 2015, and would like to share the calculations in the form of this research paper . is common) Flow rates. I'll help you get set up with the right water softener for your needs in seconds. Aquatrol Water Softening Resin Softener Media. (FRP) top-mount valve water softener calculator below. See that all analysis is ions are given as ppm CaCO3. The maximum flow rate for Water Softener Resin Is 7 gallons per minute per ft 3. Under-sizing a softener will lead to salt and water inefficiency and low-quality water while over-sizing can lead to channeling and excessive equipment costs. WATER SOFTENER SERIES 500 12 DAY TIMER INSTALLATION WATER SOFTENER SERIES 500 12 DAY TIMER INSTALLATION & OPERATING INSTRUCTIONS .2. Water Softener Hardness Removal Capacity CALCULATION N = 1000 x C D x H Select nearest lower whole number If necessary consult your dealer or IBC Water Treatment for advice on setting up the softener . If you select a water softener with less then a 30000 grain rated capacity, you could start to experience problems with hardness breakthrough, pressure drop and/or unstable water temperature in the shower. Water hardness is rated at four different tiers: Soft: 10-50 ppm/0-3 gpg. Is this for your home, RV, or business? So, the above calculation explains that if your water measures 20.76 gpg and your family uses 400 gallons of water per day, your water softener would remove about 8300 hardness grains every day. What size Softener do I need? . Simply follow the steps below. ( Use this calculator to determine the right size and system for your needs.) 1.5 Cubic Feet of Softener Resin = 30,000 Grains Capacity 2.0 Cubic Feet of Softener Resin = 40,000 Grains Capacity 3.0 Cubic Feet of Softener Resin = 60,000 Grains Capacity 4.0 Cubic Feet of Softener Resin = 80,000 Grains Capacity Do you know about Water Sediment Filter for Well Water?, if not lets have look on this below post. 4. Fleck 2900 NXT Now we have the load per cycle to calculate the resin volume we need to now calculate from the resin manufacturers data the working capacity of the resin. The grain capacity of a softener is a measure of the amount of magnesium and calcium compounds that can be removed from the water, before the softener is saturated, and should be regenerated. Step 2: Switch the Softener On. The size of water softeners is marketed in terms of grain capacity (GR). -- Water Softener Capacity Calculation For the majority of homes, our 32,000 grain unit (1 cubic foot of resin) is more than enough capacity. The Total GPD will allow you to determine what size water softener is needed based on the water softener system's grain capacity. In the service cycle, water enters the softener through the inlet distribution system and flows through the bed. Determine Boiler Horsepower. This is the amount of hardness that a water softener can remove before its resin bed and resin beads need to be regenerated. If you are sizing for Boiler, Carwash or Cooling Tower applications, use the specific water softener calculators in the right sidebar. This is because the softener is built with 1.0 cubic feet of resin. Grain capacity ranges from 120,000 to 300,000, and flow rates range from 20-40 gallons per minute. Step 1: Set Up the Softener. Once a system has reached capacity, the resin beads will be covered with . This twin-tank water softener is ideal for small multi-unit residences and small commercial spaces.